What settings should I have the PCU (plate curing unit) set for?
- The PCU is calibrated and set when it comes out of the box. The initial settings should be 190 degrees with a speed of about 1.5. During the setup process you use Thermax strips to confirm that the temperature after going through the PCU is between 150 and 160 degrees. You may need to increase or decrease the temperature control. Different conditions may affect this calibration (such as altitude, ambient temperature and humidity, etc).
Published: Sep 30, 2011
Was this helpful? Thank you for the feedback!