How do I calibrate my projector?

  • See below.

    Calibrating Automatically

    You do not need the pens or a computer for Auto Calibration.

    Note: You can start Auto Calibration by pressing the User button on the remote control or by pressing the Menu button on the remote control as described here.

    1. Press the Menu button, select the Extended menu, and press Enter.

    2. Select the Easy Interactive Function setting and press Enter.

    3. Select Auto Calibration and press Enter.

    4. Adjust the image focus, if necessary.
    5. Press Enter to select Yes. A pattern appears then disappears, and the system is calibrated. If you see a message that calibration failed, you need to calibrate manually.

    The cursor location and pen position should match after calibration. If not, you may need to calibrate manually.

    Related tasks
    Calibrating Manually

    Calibrating Manually

    If the cursor location and pen position do not match after auto calibration, you can calibrate manually.
    1. Press the Menu button, select the Extended menu, and press Enter.

    2. Select the Easy Interactive Function setting and press Enter.

    3. Select Manual Calibration and press Enter.

    4. Adjust the image focus, if necessary.
    5. Press Enter to select Yes. A flashing green circle appears in the upper left corner of your projected image.
    6. Touch the center of the circle with the tip of the pen. The circle disappears, and you see another circle below the first one.

      Note: For the most accurate calibration, make sure you touch the center of the circle.

      Note: Make sure you are not blocking the signal between the pen and the interactive receiver (next to the projection window on the projector).

    7. Touch the center of the next circle, then repeat. When you get to the bottom of the column, the next circle appears at the top of a new column.

      Note: If you make a mistake, press the Esc button on the remote control to go back to the previous circle. To restart the calibration process, press and hold the Esc button for 2 seconds.

    8. Continue until all of the circles disappear.